Selecting an EV charger control board is a critical decision for original equipment manufacturers (OEMs) developing AC wallboxes, DC charging stations, and intelligent charging systems. The controller influences charging operations, communication compatibility, safety monitoring, and integration with other electrical components.
However, not every control board provides the same functions or interfaces. Some manage complete charging operations, while others specialize in vehicle communication or backend connectivity. This guide is to explain how OEMs can evaluate controller functions, communication protocols, hardware interfaces, and integration requirements before selecting a solution.

An EV charger control board is an electronic control unit responsible for coordinating selected functions within electric vehicle supply equipment (EVSE). Depending on its architecture, it may manage charging states, monitor electrical signals, communicate with vehicles, and exchange information with backend systems.
An EV charger controller can include several functional elements:
Main charging control and monitoring.
Control pilot signal processing.
Vehicle communication interfaces.
Contactor and electronic lock control.
Fault detection and safety monitoring.
Energy metering and transaction recording.
Network and backend communication.
These functions may be integrated into one board or distributed across multiple modules.
For OEM manufacturers, selecting a suitable EV charger control board requires defining which functions are included and which must be implemented elsewhere in the charging system.
The required functions depend on charging power, equipment architecture, and application requirements.
A compact AC wallbox may need basic charging control, metering, and network communication. A commercial DC charger may require additional coordination with power modules, battery communication systems, and multiple charging connectors.
Controller Function | OEM Evaluation Criteria |
Charging control | Start, stop, and state management |
Signal monitoring | CP/PP detection and voltage monitoring |
Power management | Current limits and output coordination |
Safety monitoring | Fault detection and protective responses |
Connector control | Electronic locking and temperature sensing |
Energy metering | Meter interface and data collection |
User authentication | RFID and payment-system integration |
Backend connectivity | Remote monitoring and charging records |
Before requesting quotations, manufacturers should prepare a functional requirements document defining mandatory features, optional functions, and expected operating conditions.
AC and DC charger controllers serve different electrical architectures, so they should not be treated as interchangeable components.
In an AC charging station, the controller typically coordinates charging authorization, control pilot signaling, contactor operation, and communication with the vehicle or backend; while DC chargers require additional coordination with power conversion equipment and DC output protection systems.
For example, AUPINS AP-0515 DC charging controller specifications describe charging interaction with the battery management system, electronic lock control, temperature detection, operating data collection, and abnormal-condition shutdown.
The following comparison summarizes important differences.
Requirement | AC Charger Controller | DC Charger Controller |
Charging state control | Required | Required |
Contactor control | Common | Architecture-dependent |
Power module coordination | Generally not applicable | Often required |
Vehicle communication | IEC 61851; optional ISO 15118 | CCS, GB/T, or other applicable protocols |
Output monitoring | AC-side monitoring | DC voltage and current monitoring |
Multiple connectors | Configuration-dependent | Often supported |
OEMs should confirm the controller's supported charging standards and hardware architecture before selecting a model.

Communication compatibility is one of the most important factors in EV charger controller selection.
A suitable board must exchange information reliably with the main MCU, vehicle communication modules, meters, displays, and charging management systems.
Common interfaces include:
UART: Serial communication between embedded controllers and modules.
CAN: Communication with compatible power modules or vehicle-related systems.
RS-485: Industrial communication with meters and auxiliary devices.
Ethernet: Wired communication with network infrastructure.
Wi-Fi or 4G: Wireless connectivity for remote management.
PLC: High-level communication between compatible vehicles and charging equipment.
OEMs must distinguish physical interfaces from communication protocols. Having an Ethernet interface, for example, does not automatically guarantee OCPP compatibility.
The Open Charge Point Protocol defines standardized communication between charging stations and central management systems.
Manufacturers should verify exact protocol versions, interface electrical characteristics, supported message functions, and available integration documentation.
Successful controller integration depends on more than functional compatibility. Mechanical dimensions, electrical requirements, and signal interfaces must also match the existing charging equipment design.
Before selecting a controller, engineering teams should evaluate:
Power Supply Requirements
Confirm the operating voltage, power consumption, grounding arrangement, and protection requirements of the controller board.
Mechanical Compatibility
Check board dimensions, mounting holes, connector placement, cable routing, and available enclosure space.
Input and Output Interfaces
Verify the quantity and electrical ratings of digital inputs, relay outputs, analog inputs, and communication ports.
Environmental Requirements
Review operating temperature, humidity, electromagnetic compatibility, and vibration requirements where applicable.
Firmware Integration
Determine whether configuration tools, APIs, firmware updates, and technical documentation are available.
For example, the AUPINS' AP-SE-B ISO 15118-20 AC SECC PLC communication module provides UART communication for integration with an AC charger's main MCU. However, AP-SE-B is a communication module, not a complete charging station controller. External charging control, metering, protection, and backend functions may still be required.
Safety integration is essential when selecting an EV charger controller for commercial equipment.
The controller should support the monitoring and control functions required by the complete EVSE safety architecture.
Depending on the application, these may include:
Overcurrent and overvoltage detection.
Grounding and residual-current fault monitoring.
Connector temperature monitoring.
Emergency stop signal processing.
Contactor feedback and fault response.
Abnormal charging termination.
Software-based monitoring cannot replace required independent electrical protection devices. OEMs should clearly define which protective functions are performed by the controller, external sensors, contactors, residual-current protection devices, and other safety hardware.
The relevant requirements should be evaluated against applicable standards.
Controller selection should include verification of hardware functionality, communication compatibility, and system-level safety behavior.
A practical integration validation process includes:
Test Category | Verification Objective |
Power-up test | Confirm stable operation under specified supply conditions |
Interface test | Verify communication with connected components |
Charging sequence | Validate startup, charging, and termination |
Fault simulation | Confirm appropriate response to abnormal conditions |
Backend integration | Verify required OCPP functions |
Environmental testing | Evaluate operating temperature and EMC requirements |
Interoperability | Test compatible vehicles and charging configurations |
For projects supporting advanced vehicle communication, ISO 15118-20 provides relevant requirements for high-level vehicle-to-grid communication.
Manufacturers should conduct testing using appropriate EVSE simulators, calibrated instruments, and qualified engineering personnel.
OEM manufacturers should evaluate both technical capabilities and long-term supplier support.
A suitable supplier should provide clear product documentation, integration guidance, firmware maintenance information, and communication interface specifications.
Before confirming an order, request:
Product datasheets and interface documentation.
Hardware configuration and firmware version details.
Protocol compatibility information.
Sample availability and integration support.
Applicable test reports and compliance documentation.
Production lead times and lifecycle support arrangements.
OEM customers can compare functions of the controllers and request technical assistance based on their charging equipment requirements.
Selecting the right EV charger control board requires evaluating its complete functional scope, hardware interfaces, communication protocols, safety integration, and system compatibility. A controller that meets one charging architecture may not be suitable for another without additional hardware or software development.
For OEM manufacturers, defining technical requirements early and validating the complete charging system can reduce integration risks and simplify product development. AUPINS provides multiple EV charger controller solutions to support different AC and DC charging equipment designs.
It coordinates charging operations, monitors selected electrical signals, and communicates with connected equipment. Exact functions depend on the controller architecture.
Not necessarily. AC and DC charging equipment have different control requirements, power architectures, and communication interfaces.
Common interfaces include UART, CAN, RS-485, Ethernet, and wireless networking. The required combination depends on connected components and system architecture.
OCPP is important for chargers requiring standardized backend connectivity. However, it may be implemented through a separate communication module.
No. An SECC module handles vehicle communication, while the complete charging system may require additional controllers, metering, and safety hardware.
OEMs should check functional compatibility, interface specifications, protocol versions, electrical ratings, mechanical dimensions, testing requirements, and supplier support.
n e x t